APPLICATION
 | HYCON RF and RFD In-Tank Return Line Filters
are designed for use on hydraulic power units, machine tools, plastics machinery, mobile
equipment, and hydraulic test equipment. |
 | These filters are also suitable for lubrication and coolant filtration
applications. |
 | These filters can be installed in the reservoir on the return side of the system
to capture all system-generated contamination. |
 | These filters can also be used as In-line Return Line Filters. |
PRODUCT FEATURES
 | Non-welded housing design reduces stress concentrations and prevents fatigue
failure. |
 | Inlet/outlet port options include NPT port, SAE straight thread O-ring boss, and
SAE 4-bolt flange to allow easy installation without costly adaptors. |
 | O-ring seals are used to provide positive, reliable sealing. Choice of O-ring
materials (Buna-N, Fluorocarbon, EPR) provides compatibility with petroleum oils,
synthetic fluids, water-glycols, oil/water emulsions, and high water base fluids. |
 | Bolt-on lid (RF 30 lid screws on) requires minimal clearance for removal. |
 | Reusable contamination basket prevents loss of retained contaminants into the
reservoir during element replacement. |
 | Clogging indicators can be serviced without interruption of the hydraulic system. |
 | All RFD duplex filters have a ball-type selector valve to
provide continuous filtration without system shut-down to change clogged elements. |
|
 |
HYCON FILTER ELEMENTS
 | HYCON RF and RFD filters are available with disposable
BetamicronŽ BNHC elements having 250 PSID collapse pressure and absolute ratings of 3, 5,
10 and 20 micron. |
 | HYCON RF and RFD filters are also available
with cleanable elements. Wire screen (W) elements have a 250 PSID collapse
pressure and nominal ratings of 25, 74, 149 microns. |
 | For applications which do not require fine filtration, disposable HYCON
paper (P) elements may be selected. Paper elements have a 145 PSID collapse pressure and
nominal ratings of 10 and 20 microns. |
 | All filter media is supported to achieve flow fatigue resistance. |
 | Proper support of the filter media also provides high Beta Ratio values (particle
removal efficiency) even at high differential pressures. The efficiency of many
competitive elements drastically deteriorates as the element clogs and differential
pressure increases. |
 | High quality epoxy adhesive is used to bond the end caps to the media and to bond
the seam of the media. |
 | All elements available for HYCON RF and RFD
filters have the bypass valve built into the filter element. As a result, a new bypass
valve is provided each time the element is changed, making it less likely that a bypass
valve will stick open, jam, or fail through fatigue. |
|
|